0 Compare
Add products to the comparison using the scales icon and here you can then compare their parameters.
User
0 Basket
Your basket is empty...

Xgard Type 3 for methane (CH4), 0-100% LEL (VQ21T), SS body, M20, ATEX

Xgard Type 3 is flameproof flammable gas detector. Poison resistant pelistors are used to detect flammable gasses.

Your price
on inquiry
Availability: ask us
Product description

Product description

Xgard Type 3

is flameproof flammable gas detector. Poison resistant pelistors are used to detect flammable gasses.

Main features

  • low cost of ownership
  • easy installation and maintenance, simple replacement of senzors
  • flexible installation options
  • rugged and reliable
  • made from stainless steel (SS 316), spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
  • ATEX certificate

Czech datasheet in pdf for XGARD detector can be found at this link https://www.chromservis.eu/…as-detection.

Parameters

Parameters

Brand: XGARD
Category: Measurement and control / Gas measurement / Fixed detectors

Technical specifications

Dimensions 156 mm x 166 mm x 111 mm
Weight 3,1 kg
Ingress protection IP65, IP66 with weatherproof cap
Cable entries 1 x M20
Terminations 0.5 – 2.5 mm2 csa (20–13 awg)
Sensor type pellistor – VQ21T
Operating temperature –40 až 80 °C
Humidity 0–99% RH
Zero drift < 2% FSD/month
Response time T90 < 15 s
Operating voltage 2.0 V +/- 0.1 V
Power reguirements 300 mA
Electrical output 3-wire mV bridge
Approvals ATEX Ex II G, EExd IIC T6

Available gases and ranges*

Acetylene 0–100% LEL
Ammonia 0–25% LEL
Butane 0–100% LEL
Ethane 0–100% LEL
Ethylene 0–100% LEL
Hydrogen 0–100% LEL
LPG 0–100% LEL
Methane 0–100% LEL
Pentane 0–100% LEL
Petrol 0–100% LEL
Propane 0–100% LEL
Vinyl Chloride 0–100% LEL

*One detector is for one gas and one range, therefor it's needed to refer to the relevant part number in case of your interest **Other sensors and ranges maybe available, please contact Chromservis s.r.o.

Use

Gas detectedCH4

Operating conditions

ATEXATEX
Detection/Operation principlePellistor
Product inquiry
Visited (1)