0 Compare
Add products to the comparison using the scales icon and here you can then compare their parameters.
User
0 Basket
Your basket is empty...

PC 80 Pro DHS kit with pH electrode and conductivity cell (CHS Sleeve S7, CHS CondiLab 22P), included stirrer, cable S7/BNC, temperature probe, buffers and electrode holder

Laboratory pH/mV/ION/CON­D/TDS/Salinity/Re­sistivity/Tem­peratury meter PC 80 Pro is equipped with a large colour and contrast graphical display that user intuitively directs during the measurement and calibration.

Your price
on inquiry
Availability: ask us
Product description

Product description

Laboratory pH/mV/ION/CON­D/TDS/Salinity/Re­sistivity/Tem­peratury meter PC 80 Pro is equipped with a large colour and contrast graphical display that user intuitively directs during the measurement and calibration.

Additionally the display shows measured values and the values of buffers, which were used for calibration, electrode status and GLP functions. pH-meter supports automatic buffer recognition and is equipped with a magnetic stirrer including electrode holder.

  • Kit includes pH electrode CHS Sleeve S7 and conductivity cell CHS Condilab 22P
Parameters

Parameters

Brand: CHS
Category: Laboratory instruments and accessories / Apparatus for measuring samples / Multiparameter instruments

Measuring values and ranges

Parameter Value Range
pH measuring range –2 to 20 pH
Resolution 0.1/0.01/0.001
Relative accuracy ±0.002
Points of calibration 1 to 5
Buffer recognized USA,NIST,DIN,5 de­fined by user
ORP Range −2 000 to +2 000 mV
Resolution 0,1/1 mV
ION Range 0,001 to 19 000 ppm
Units mol/l – mg/l – g/l
Calibratio 2..5
Conductivity Range 0,00..20,00 – 200,0 – 2000 µS; 2,00 – 20,00 – 200,0 – 1 000 mS
Resolution automatic
Accuracy ±1% full range
Calibration 1..4
TDS Range 0,1 mg/l to 500 g/l
TDS faktor/Přesnost 0,40..1,00/±1% z celkového rozsahu
Salinity Range 0,01 to 100 ppt
Accuracy ±1% full range
Resistivity Range 1 to 10 MΩ
Accuracy ±1% full range
Temperature measuring range –20 to 120°C
Resolution/Accuracy 0.1/±0.2°C

Technical parameters

Indication of calibration points YES
Indication electrode condition YES
Alarm setting for the measurement Icon (Low-Medium-High)
Temperature compensation Manual or automatic (NTC 30KΩ) 0 to 100°C
Temperature Calibration YES
Display Multicolor dot matrix, high resolution, digital or analogical view
Inputs 2×BNC, 2×Cinch/RCA(AT­C),2×USB, RS-232
Manual on-line integrated – english
Magnetical stirrer YES, Removable
Speed control 0 to 3000 rpm
Protection IP54
Power supply AC/DC adapter 12V/1000mA
Dimensions 165 × 195 × 68 mm
Weight 1050g

Use

Phys. propertyMULTI
Instrument typeTable
Product inquiry
Visited (1)