High flows from 5 to 15 L/min Achieve flow rates that you couldn't reach before when using a personal sample pump. The Leland Legacy® provides the high flow and long run-times of a vacuum-style pump in a compact, portable, and battery-operated sampler.

Your price
on inquiry
Availability: ask us
Product description

Product description

High flows from 5 to 15 L/min

Achieve flow rates that you couldn't reach before when using a personal sample pump. The Leland Legacy® provides the high flow and long run-times of a vacuum-style pump in a compact, portable, and battery-operated sampler.

Long runs for 24 hours on one battery charge

Rechargeable lithium-ion (Li-Ion) battery pack will provide 24-hour run times with impactors and other sampling devices with low back pressures*. Leland Legacy is ideal for 24-hour indoor air studies and unattended ambient air sampling.

Typical Run Time:

  • Sioutas Impactor (13 in water bp): 24 hrs at 9 L/min
  • PEM with 37-mm, 2.0 µm PTFE filter 225–1709‡: 24 hrs at 10 L/min
  • Low Volume PUF Tube: 24 hrs at 5 L/min
  • DPS Sampler: 24 hours at 10 L/min

Low Noise

With the noise reducing case accessory, the Leland Legacy can operate at 10 L/min and 12 inches water back pressure with a noise level of only 52 dBA@3m

Highly accurate calibration

The patented (U.S. Patent Nos. 6,227,031 and 6,363,769) built-in CalChek feature provides direct communication to a DC-Lite (Defender) primary standard for fast and easy calibration without manual adjustments. (Defender Calibrator required for CalChek is sold separately or in convenient Leland Legacy CalChek pump kits).

Technical parameters

Flow Range 5 to 15 l/min
Flow Control System Closed loop with patented internal flow sensor
Compensation Range 15 l/min at 5" H2O, 10 l/min at 12 "H2O, 5l/min at 20 "H2O
Accuracy – flow rate ± 5% of set-point after calibration to desired flow
Accuracy – timing 1 min/month @ 25 C
Accuracy – atmospheric pressure ± 0.3 "Hg
Flow Fault If the pump is unable to compensate for >15 seconds due to excessive back pressure, a flow fault icon displays and flashes, the pump enters Hold mode, and the pump retains historical data. Auto restart is attempted every 20 seconds up to 10 times. Adjustable with DataTrac for Leland Legacy software
Size 20 × 10 × 7 cm
Weight 1 kg
Parameters

Parameters

Brand: Leland Legacy
Category: Laboratory instruments and accessories / Air Sampling / Sampling pumps

Operating conditions

ATEXGeneral use
Pump Maximum Flowrate15000ml/min
Pressure compensationano
Programmingano